Back to Top

1
Hi, Guest!

  LOKASI :  Kabupaten Semarang

BAGIKAN :   

Bagikan :
Kontak Kami  
Multi Sarana Industrindo sebagai agent dan distributor berbagai kebutuhan perusahaan anda dengan bermacam-macam merk dan product seperti + GF+ SI

Guided Radar E+ H Levelflex M FMP41C

Update Terakhir
:
04 / 04 / 2023
Min. Pembelian
:
1 Unit

Harga

CALL
Bagikan
:
Multi Sarana Industrindo sebagai agent dan distributor berbagai kebutuhan perusahaan anda dengan bermacam-macam merk dan product

Detail Guided Radar E+ H Levelflex M FMP41C

Continuous Level Transmitter for - Level Measurement in Liquids - Interface Measurement in Liquids Your benefits Measurement independent of product properties as: - density, - dielectric constant, - conductivity. Measurement is also possible in the event of foam or if the surface is very turbulent. Simple, menu-guided onsite operation with four-line plain text display. Easy remote operation, diagnosis and measuring point documentation with the free operating program supplied. Optional remote display and operation. Onsite envelope curve on the display for easy diagnosis. Electronics can be replaced without opening the tank. Application in safety related systems ( overspill protection) with requirements for functional safety up to SIL 2 in accordance with IEC 61508/ IEC 61511-1. Approvals: - Europe: ATEX, EHEDG, steam boiler EN 12952-11/ EN 12953-9. - North America: FM, CSA. Field of application Level measurement The Levelflex M is used for continuous level measurement of liquids. FMP41C for corrosive liquids and hygienic requirements Highest chemical resistance. Rod probes up to 4 m ( 157" ) , rope probes up to 30 m ( 1181" ) measuring range. with rod probe also for food processing and pharmaceuticals. All wetted components: PTFE, FDA-listed, gap-free. The following interfaces are available for system integration: HART ( standard) with 4 to 20 mA analog, PROFIBUS PA, FOUNDATION Fieldbus. Interface measurement Continuous measurement of interfaces between two liquids with very different dielectric constants, such as in the case of oil and water for example. Measurement independent of density, conductivity and temperature. Electronics version for the simultaneous measurement of the level of interfaces and the total level in liquids. The HART with 4 to 20 mA analog protocol is available for system integration. Special version for the measurement of the level of interfaces at a constant total level. The PROFIBUS PA and FOUNDATION Fieldbus protocols are available for system integration. Order information
Tampilkan Lebih Banyak